CONFigure:LTE:MEAS<i>:MEValuation:SCONdition
<StopCondition>
Qualifies whether the measurement is stopped after a failed limit check or continued.
SLFail
means that the measurement is stopped and reaches the
RDY
state as soon
as one of the results exceeds the limits.
Parameters:
<StopCondition>
NONE | SLFail
NONE:
Continue measurement irrespective of the limit check
SLFail:
Stop measurement on limit failure
*RST:
NONE
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V1.0.10.1
Manual operation:
See
CONFigure:LTE:MEAS<i>:MEValuation:MMODe
<MeasurementMode>
Selects the measurement mode.
Parameters:
<MeasurementMode> NORMal | TMODe | MELMode
NORMal
: normal mode
TMODe
: TPC mode
MELMode
: multi evaluation list mode
*RST:
NORM
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.1.20
Options:
R&S CMW-KM012 for MELMode
Manual operation:
See
CONFigure:LTE:MEAS<i>:MEValuation:TMODe:SCOunt
<SubframeCount>...
Defines the subframe counts for all entries of the "TPC Mode" list.
For definition of the corresponding expected nominal power values, see
.
Parameters:
<SubframeCount>
Comma separated list of 16 values, for list entry number 0 to 15
Range:
1 to 320
*RST:
320
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.1.30
Manual operation:
See
Command Reference
135-1095-0799