CALCulate:LTE:MEAS<i>:MEValuation:ESFLatness:CURRent?
CALCulate:LTE:MEAS<i>:MEValuation:ESFLatness:AVERage?
CALCulate:LTE:MEAS<i>:MEValuation:ESFLatness:EXTReme?
Return current, average and extreme single value results of the equalizer spectrum
flatness measurement. See also
chapter 3.2.5.6, "Equalizer Spectrum Flatness Limits"
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<OutOfTolerance>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for modulation measurements exceed-
ing the specified equalizer spectrum flatness limits.
Range:
0 % to 100 %
Default unit: %
<Ripple1>
Max (Range 1) - Min (Range 1)
Range:
0 dB to 40 dB
Default unit: dB
<Ripple2>
Max (Range 2) - Min (Range 2)
Range:
0 dB to 40 dB
Default unit: dB
<MaxR1MinR2>
Max (Range 1) - Min (Range 2)
Range:
-40 dB to 40 dB
Default unit: dB
<MaxR2MinR1>
Max (Range 2) - Min (Range 1)
Range:
-40 dB to 40 dB
Default unit: dB
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.20
FETCh:LTE:MEAS<i>:MEValuation:ESFLatness:CURRent:SCINdex?
Returns subcarrier indices of the equalizer spectrum flatness measurement. At these
SC indices the current minimum and maximum power of the equalizer coefficients
have been detected within range 1 and range 2.
Return values:
<Reliability>