User Manual 1173.9628.02 ─ 16
CONFigure:LTE:MEAS<i>:MEValuation:RESult:BLER
<Enable>
CONFigure:LTE:MEAS<i>:MEValuation:RESult:PDYNamics
<Enable>
Enables or disables the evaluation of results and shows or hides the views in the multi
evaluation measurement.
The mnemonic after "RESult" denotes the view type: Error Vector Magnitude, Magni-
tude Error, Phase Error, Inband Emissions, EVM vs. Subcarrier, I/Q Constellation Dia-
gram, Equalizer Spectrum Flatness, TX Measurement Statistical Overview, Spectrum
Emission Mask, Adjacent Channel Leakage Power Ratio, Resource Block Allocation
Table, Power Monitor, Block Error Ratio, Power Dynamics.
.
Parameters:
<Enable>
OFF | ON
OFF:
Do not evaluate results, hide the view
ON:
Evaluate results and show the view
*RST:
Depends on measurement
Firmware/Software:
V1.0.10.1
RBATable and PMONitor: V1.0.15.20
BLER: V1.0.15.21
ESFLatness, PDYNamics: V2.0.10
Manual operation:
See
"Multi Evaluation > Assign Views"
3.5.3.3
Measurement Parameters - General Part
The following commands define general measurement control parameters for the multi
evaluation measurement.
CONFigure:LTE:MEAS<i>:MEValuation:TOUT
................................................................. 601
CONFigure:LTE:MEAS<i>:MEValuation:REPetition
........................................................... 601
CONFigure:LTE:MEAS<i>:MEValuation:SCONdition
......................................................... 602
CONFigure:LTE:MEAS<i>:MEValuation:MMODe
.............................................................. 602
CONFigure:LTE:MEAS<i>:MEValuation:TMODe:SCOunt
...................................................602
CONFigure:LTE:MEAS<i>:MEValuation:TMODe:ENPower
................................................ 603
CONFigure:LTE:MEAS<i>:MEValuation:TMODe:RLEVel?
................................................. 603
CONFigure:LTE:MEAS<i>:MEValuation:MOEXception
...................................................... 603
CONFigure:LTE:MEAS<i>:MEValuation:ULDL
.................................................................. 604
CONFigure:LTE:MEAS<i>:MEValuation:SSUBframe
......................................................... 604
CONFigure:LTE:MEAS<i>:MEValuation:CPRefix
.............................................................. 605
CONFigure:LTE:MEAS<i>:MEValuation:CTYPe
................................................................605
CONFigure:LTE:MEAS<i>:MEValuation:PFORmat
............................................................605
CONFigure:LTE:MEAS<i>:MEValuation:NSValue
............................................................. 606
CONFigure:LTE:MEAS<i>:MEValuation:NSValue:CAGGregation
....................................... 606
CONFigure:LTE:MEAS<i>:MEValuation:NVFilter
...............................................................606
CONFigure:LTE:MEAS<i>:MEValuation:CTVFilter
.............................................................607
CONFigure:LTE:MEAS<i>:MEValuation:RBALlocation:AUTO
.............................................607
CONFigure:LTE:MEAS<i>:MEValuation:RBALlocation:NRB
...............................................608
CONFigure:LTE:MEAS<i>:MEValuation:RBALlocation:ORB
...............................................608