![R&S CMW-KM5 Series User Manual Download Page 592](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802592.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
592
User Manual 1173.9628.02 ─ 16
CONFigure:LTE:MEAS<i>:RFSettings:FOFFset
<Offset>
Specifies a positive or negative frequency offset to be added to the carrier center fre-
quency (
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use
Parameters:
<Offset>
Range:
-100E+3 Hz to 100E+3 Hz
*RST:
0 Hz
Default unit: Hz
Example:
See
Specifying General and Common Measurement Settings
Firmware/Software:
V3.2.10
Manual operation:
See
CONFigure:LTE:MEAS<i>:RFSettings:ENPower
<ExpNomPow>
Sets the expected nominal power of the measured RF signal.
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use:
●
●
Parameters:
<ExpNomPow>
The range of the expected nominal power can be calculated as
follows:
Range (Expected Nominal Power) = Range (Input Power) +
External Attenuation - User Margin
Range:
-47 dBm to 55 dBm for the input power at the RF
COM connectors (please notice also the ranges
quoted in the data sheet)
*RST:
0 dBm
Default unit: dBm
Example:
See
Specifying General and Common Measurement Settings
Firmware/Software:
V1.0.10.1
V3.0.10: enhanced range
Manual operation:
See
CONFigure:LTE:MEAS<i>:RFSettings:UMARgin
<UserMargin>
Sets the margin that the R&S
CMW adds to the expected nominal power in order to
determine its reference power. The reference power minus the external input attenua-
tion must be within the power range of the selected input connector; refer to the data
sheet.
Command Reference
深圳德标仪器
135-1095-0799