User Manual 1173.9628.02 ─ 16
FETCh:LTE:MEAS:MEValuation:LIST:ESFLatness:MAXR2:AVERage?
FETCh:LTE:MEAS:MEValuation:LIST:ESFLatness:SCINdex:MINimum1:CURRent?
// *****************************************************************************
// Return selected spectrum emission and ACLR results.
// *****************************************************************************
FETCh:LTE:MEAS:MEValuation:LIST:SEMask:OBW:AVERage?
FETCh:LTE:MEAS:MEValuation:LIST:SEMask:TXPower:MAXimum?
FETCh:LTE:MEAS:MEValuation:LIST:SEMask:MARGin:AREA5:NEGativ:MINimum?
FETCh:LTE:MEAS:MEValuation:LIST:ACLR:EUTRa:AVERage?
FETCh:LTE:MEAS:MEValuation:LIST:ACLR:EUTRa:NEGativ:AVERage?
FETCh:LTE:MEAS:MEValuation:LIST:ACLR:UTRA2:POSitiv:AVERage?
// *****************************************************************************
// Return detected allocation, modulation scheme and channel type of the
// last slot within the statistical length of the modulation measurement.
// *****************************************************************************
FETCh:LTE:MEAS:MEValuation:LIST:MODulation:DALLocation?
FETCh:LTE:MEAS:MEValuation:LIST:MODulation:DMODulation?
FETCh:LTE:MEAS:MEValuation:LIST:SEMask:DCHType?
// *****************************************************************************
// Return the individual segment reliability indicators
// *****************************************************************************
FETCh:LTE:MEAS:MEValuation:LIST:SRELiability?
3.5 Command Reference
The following sections provide detailed reference information on the remote control
commands of the "LTE Multi Evaluation" measurement and the general commands
applicable to all LTE measurements.
Conventions and General Information
.................................................................. 580
............................................................................ 584
Multi Evaluation Measurement Commands
.......................................................... 595
.......................................................................726
3.5.1 Conventions and General Information
The following sections describe the most important conventions and general informa-
tions concerning the command reference.
3.5.1.1
MEAS<i>
MEAS<i> is used as abbreviation of "MEASurement<instance>". For better readability
only the abbreviated form (which is also accepted by the instrument) is given in the
command reference.