R&S AFQ100A
AFQ Commands - Signal Generation
1401.3084.32 6.33
E-3
External
The segment trigger event is executed with the aid of the active edge of an
external trigger signal. The trigger signal is supplied via NEXT connector.
Bus
The segment trigger event is executed by remote control using the command
TRIG:SEGM:EXEC
.
Auto
The segment trigger event is executed internally by the firmware. Signal
output starts immediately when ARB modulation is enabled, trigger events are
ignored (segment mode Single or Repeat N Times only).
Note:
The Trigger Source
Auto
disables the Segment Modes
Continuous
and
Continuous Seamless
and vice versa.
Example:
TRIG:SEGM:SOUR AUTO
'selects the segment trigger source.
*RST value
Resolution
Options
SCPI
MANual -
Device-specific
[SOURce:]TRIGger:SOURce
MANual | EXTernal | BUS | AUTO
The command selects the trigger source.
Parameter:
Manual
The trigger event can be executed by pressing the TRIG key on the front
panel or by clicking the
Execute
button, which is displayed in Manual mode
only. As a precondition a trigger mode other than
Auto
must be selected.
External
The trigger event is executed with the aid of the active edge of an external
trigger signal. The trigger signal is supplied via the TRIG connector on the rear
panel.
Bus
The trigger event is executed by remote control using either the command
*GET, *TRG or TRIG:EXEC.
Auto
The trigger event is executed internally by the firmware.
Example:
TRIG:SOUR EXT
'sets an external triggering.
*RST value
Resolution
Options
SCPI
AUTO -
Device-specific