Run Mode "
Single
"
Each segment trigger event switches to the next
segment. A regular trigger event resets signal
generation.
Run Mode "
Repeat N Times
"
Each segment trigger event switches to the next
segment. A regular trigger event resets signal
generation. Generation of the multi segment
waveform is repeated as often as
Repeat Count
of the regular trigger mode is set.
Remote-control command:
SOUR:TRIG:SEGM:MODE SING
Repeat N Times
Multiple output of the waveform segments. Each
segment is repeated as often as the segment
Repeat Count
of the particular segment is set
(see
Repeat Count
, on page 4.22).
Run Mode "
Continuous
"
The next segment starts to be output after a
segment trigger event. After finishing the
waveform the instrument switches to the idle
mode. Either a segment or a regular trigger event
restart signal generation.
Run Mode "
Single
"
The next segment starts to be output after a
segment trigger event. After finishing the
waveform the instrument switches to the idle
mode. The waveform output can be restarted by
switching off and then switching on the ARB state