E-3
Inhibit - Trigger
Sets the duration for inhibiting a new trigger event subsequent to
triggering. A restart can only be inhibited with an external trigger
source.
In the
Retrigger
mode every trigger signal causes signal output to
restart. This restart is inhibited for the specified number of samples.
Remote-control command:
SOUR:TRIG:EXT:INH 10
Slope - Trigger
Selects the slope of the active edge of an external trigger signal. The
trigger signal is fed in via the TRIG connector on the rear panel. The
slope can only be selected with an external trigger source.
Positive
The rising edge is selected.
Remote-control command:
SOUR:INP:TRIG:SLOP POS
Negative
The falling edge is selected.
Remote-control command:
SOUR:INP:TRIG:SLOP NEG