4-1
Section 4
Power Supply and Distribution
4-1 AC Power (Refer to Figure 4-1)
The AC power is supplied to the PantherPro/46 through the removable power cord that plugs
into the receptacle located on the rear of the unit. The receptacle is part of the main power
switch assembly module, which also includes the main AC fuse, and RFI filter. The module
can be used for 115 VAC and 230 VAC operation and is converted by turning the fuse
housing and lining up the arrowhead with the horizontal line on the module housing and by
setting the jumpers on the Power Supplies.
Note: The Condor Power Supply jumpers are soldered.
CAUTION: For continued protection against fire hazard, replace fuse only with same type
and rating.
110-120V
220-240V
220-240V
110-120V
Main ON/OFF Switch
Fuse Housing
For 115V Use 4A
For 230V Use 2.5A
115V Position
230V Position
Main Power Switch Module Voltage Positions
Figure 4-1
The neutral and hot wires from the main switch module are connected to the AC input
terminals on the power supplies. The ground wire is connected to the chassis. (Refer to
Figure 4-2 AC Distribution Diagram)