PantherPro/46 Image Recorder
TP8251
October 1995
PrePRESS SOLUTIONS CONFIDENTIAL
9-13
B - 2400 Baud
C - 9600 Baud
D - 19200 Baud
Q - Quit After Saving
Enter Selection or ESC to Abort :
Press ESCAPE to return to Diagnostic Menu
Enter option "B", to enable/disable Level 2 Power-up Diagnostics Tests.
The following menu will be displayed:
Level2 Diagnostics Power-on Mode [Disabled]
E - Enable Level2 Power-on Diagnostics
D - Disable Level2 Power-on Diagnostics
Q - Quit After Saving
Enter Selection or ESC to Abort :
Press ESCAPE to return to Diagnostic Menu
Enter option "D", to display/modify control Register
CONTROL REGISTER EDITOR
Bit 31 - LED MSB
1
Bit 15 - CPU -> IMG 0
Bit 30 - LED 7th
1
Bit 14 - PBM4-> IMG 0
Bit 29 - LED 6th
1
Bit 13 - PBM3-> IMG 0
Bit 28 - LED 5th
1
Bit 12 - PBM2-> IMG 0
Bit 27 - LED 4th
1
Bit 11 - PBM1-> IMG 0
Bit 26 - LED 3rd
1
Bit 10 - PBM0-> IMG 0
Bit 25 - LED 2nd
0
Bit 9 - Ena PBM0 ints 0
Bit 24 - LED LSB
0
Bit 8 - Ena PBM1 ints 0
Bit 23 - Beep MSB
0
Bit 7 - Ena PBM2 ints 0
Bit 22 - Beep 7th
0
Bit 6 - Ena PBM3 ints 0
Bit 21 - Beep 6th
0
Bit 5 - Ena PBM4 ints 0
Bit 20 - Beep 5th
0
Bit 4 - LCD timer 1
Bit 19 - Beep 4th
0
Bit 3 - DeadMan timer 1
Bit 18 - Beep 3rd
0
Bit 2 - unused 0
Bit 16 - Beep LSB
0
Bit 0 - PBTest 0
Enter bit(s) to set/clear, 'h' for help or 'q' to quit
PRESS "Q" to quit, to return to the Diagnostic Menu
Enter option "E" to display/modify system debug registers.