236
Po302
N
INT16
RW
Please refer to 9.3.3
Sub-index 04h
Position loop feed forward gain PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1000
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po303
N
INT16
RW
Please refer to 9.3.3
Sub-index 05h
First group electronic gear numerator PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
65535
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po304
N
INT16
RW
The entry-into-effect time is 100ms.
Sub-index 06h
First group electronic gear denominator PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
65535
N/A
10000
Immediate
Function code
Mapping
Data type
Accessibility
Po305
N
INT16
RW
The entry-into-effect time is 100ms.
Sub-index 07h
Position loop filter time constant PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
10000
ms
1
Immediate
Function code
Mapping
Data type
Accessibility
Po306
N
INT16
RW
Please refer to 9.3.3
Sub-index 09h
Command pulse clear function PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
Four-parameter
N/A
—
Immediate
Function code
Mapping
Data type
Accessibility
Po308
N
INT16
RW