205
2008h-2Ah
DI4 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po441
N
UINT16
RW
2008h-2Bh
DI5 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po442
N
UINT16
RW
2008h-2Ch
DI6 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po443
N
UINT16
RW
2008h-2Dh
DI7 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po444
N
UINT16
RW
2008h-2Eh
DI8 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po445
N
UINT16
RW
7.10.8 Touch probe function
Touch probe function is position latch function, which can latch position when DI or motor Z
signal is changing.
1
)
Related objects
Index
Sub-
index
Name
Access
Data
type
Unit
Setting
Range
Mfr’s
Value
2004h
0Eh
DI7terminal
function
RW
UINT16
-
Two-
parameter
d1 34