273
Index
6099h-02h
Second Homing speed
HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
20000
0.1rpm
200
Immediate
Function code
Mapping
Data type
Accessibility
Po121
N
UINT16
RW
The entry-into-effect time is 100ms.
Index 609Ah
Homing acceleration
HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1000
ms
0
Immediate
Function code
Mapping
Data type
Accessibility
—
N
UINT16
RW
Index 60B0h
Position offset
CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
-2
31
~
(
2
32
-1
)
Command unit
0
Immediate
Function code
Mapping
Data type
Accessibility
—
RPDO
DINT32
RW
The entry-into-effect time is 100ms.
Index 60B1h
Velocity offset
CSP CSV
Setting Range
Setting Unit
Mfr’s Value
Effect
-1300000
~
1300000
0.01rpm
0
Immediate
Function code
Mapping
Data type
Accessibility
—
RPDO
DINT32
RW
Index 60B2h
Torque offset
CST
CSP CSV
Setting Range
Setting Unit
Mfr’s Value
Effect
-1000~1000
0.1%
0
Immediate
Function code
Mapping
Data type
Accessibility
—
RPDO
INT16
RW