231
Po221
N
INT16
RW
Please refer to 9.4.
Sub-index 17h
The second notch filter depth
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
100
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po222
N
INT16
RW
Please refer to 9.4.
Sub-index 18h
The third notch filter center frequency
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
50
~
30000
Hz
2000
Immediate
Function code
Mapping
Data type
Accessibility
Po223
N
INT16
RW
Please refer to 9.4.
Sub-index 19h
The third notch filter width
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
30000
Hz
5
Immediate
Function code
Mapping
Data type
Accessibility
Po224
N
INT16
RW
Please refer to 9.4.
Sub-index 1Ah
The third notch filter depth PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
100
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po225
N
INT16
RW
Please refer to 9.4.
Sub-index 1Bh
The fourth notch filter center frequency
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect