198
Deceleration point:
home switch
-H
-L
Home switch
Home switch signal
Motion profile
Negative limit switch
The ORGP signal is inactive initially. The motor starts homing in negative direction at high
speed. If the motor does not reach the limit switch, it decelerates and continues to run in
negative direction at low speed after reaching the rising edge of the ORGP signal. After
reaching the falling edge of the ORGP signal, the motor stops.
b
)
Deceleration point signal inactive at homing start, reaching negative limit switch
-H
-L
H
Home switch
Home switch signal
Motion profile
Negative limit switch
Negative limit signal
The ORGP signal is inactive initially, and the motor starts homing in negative direction at high
speed. If the motor reaches the limit switch, it automatically changes to run in positive direction
at high speed. After reaching the rising edge of the ORGP signal, the motor decelerates and
changes to run in negative direction at low speed.
After reaching the falling edge of the ORGP signal, the motor stops.
c
)
Deceleration point signal active at homing start