228
Sub-index 2Bh
Forward running range multi-loop numbers when overtravel
protection PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
32000
N/A
1000
Immediate
Function code
Mapping
Data type
Accessibility
Po142
N
RW
INT16
Sub-index 2Ch
Reverse running range pulse when overtravel protection
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
2
31
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po143
N
DINT32
RW
Sub-index 2Eh
Reverse running range multi-loop numbers when overtravel
protection PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
32000
N/A
1000
Immediate
Function code
Mapping
Data type
Accessibility
Po145
N
RW
INT16
8.3.4 Index segment 2002h (function code Po2
□□
)
Sub-index 01h
First current loop bandwidth PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
10
~
3000
Hz
—
Immediate
Function code
Mapping
Data type
Accessibility
Po200
N
INT16
RW
Please refer to 9.3.3.
Sub-index 02h
Second current loop bandwidth PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
10
~
3000
Hz
—
Immediate
Function code
Mapping
Data type
Accessibility