203
2008h-26h
Motor overload coefficient setting PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1~500
%
100
Immediate
Function code
Mapping
Data type
Accessibility
So-37
N
UINT16
RW
3
Overload times
0
2
2.2
2.4
2.6
2.8
1.2
1.4
1.6
1.8
600
500
400
300
200
100
alarm
time
unit
(
S
)
wi
th
So
-3
7i
nc
re
as
in
g,c
ur
ve
m
ov
es
t
o
u
pp
er
r
ig
ht
So-37=100
So-37>100
Fig 7.10.1Motor overload curve and alarm time curve graph
(2)
Motor lock-rotor protection
Motor speed is almost 0 when servo-motor lock-rotor occurs, but actual current is very high,
servo drive and servo motor may be damaged because of long time lock-rotor, therefore, servo
drive provides the motor lock-rotor protection to prevent the damage from excessive
temperature in the situation of motor lock-rotor.
Related Parameter
2008h-23h
Motor lock-rotor protection PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~1
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
So-34
N
UINT16
RW
2008h-29h
Delay time of lock-rotor protection PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
10~1000
10ms
100
Immediate
Function code
Mapping
Data type
Accessibility
So-40
N
UINT16
RW
(3)
Motor overheat protection
2008h-33h
Motor overheat protection PP PV PT CSP CSV CST HM
Setting range
Setting unit
Mfr’s value
When enabled