204
7.10.7 DI Terminals Filter Function
Servo drive has 8 DI terminals.
DI terminal filter setting: if terminal signal has interference, users can carry on filter processing
by setting 2008h-27h
~
2008h-2Eh.
2008h-27h
DI1 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po438
N
UINT16
RW
2008h-28h
DI2 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po439
N
UINT16
RW
2008h-29h
DI3 filter time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0~30000
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
Po440
N
UINT16
RW
0~1
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
So-50
N
UINT16
RW
0: Invalid 1: Valid
2008h-34h
Motor disconnected protection of temperature detection
PP V PT CSP CSV CST HM
Setting range
Setting unit
Mfr’s value
When enabled
0~1
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
So-51
N
UINT16
RW
0: Invalid 1: Valid