212
Accessibility:
Refer to below table:
Accessibility Definition
RW
Read-write
WO
Write only
RO
Read only
CONST
Constant
,
read only
Mapping
: Refer to below table:
Mapping Definition
NO
No mapping in PDO
RPDO
Write only
TPDO
Read only
Master station sets parameter by SDO.
If setting value is larger than upper limit, drive returns to abort message 13h.
If setting value is smaller than lower limit, drive returns to abort message 14h.
If user modifies parameter that is not allowed to be modified in running state, drive returns to
1Ah.
If user password is not entered, drive returns to abort message 19h.
8.2 Communication parameter (1000h~1FFFh)
Index 1000h
Device type
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
N/A
N/A
00020192h
—
Function code
Mapping
Data type
Accessibility
—
N
UDINT32
RO
Index 1001h
Error register PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
N/A
N/A
—
—
Function code
Mapping
Data type
Accessibility
—
N
USINT8
RO
Index 1009h
Hardware version PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
N/A
N/A
—
—
Function code
Mapping
Data type
Accessibility
—
N
STRING24
RO
Index 100Ah
Software version
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect