15-2
Parameter Reference
AC10 Inverter
Function
Code
Function
Definition
Setting Range
Mfr’s Value Change
F125
Jogging Acceleration Time
0.1
~
3000S
subject to
inverter
model
√
F126
Jogging Deceleration Time
0.1
~
3000S
√
F127
Skip Frequency A
0.00
~
590.0Hz
0.00
√
F128
Skip Width A
±2.50Hz
0.00
√
F129
Skip Frequency B
0.00
~
590.0Hz
0.00
√
F130
Skip Width B
±2.50Hz
0.00
√
F131
Running Display Items
0
-
Output frequency /
function code
1
-
Output RPM
2
-
Output current
4
-
Output voltage
8
-
DC Bus Voltage
16
-
PID feedback value
32
-
Temperature
64
-
Reserved
128
-
Linear speed
256
-
PID given value
512
-
Reserved
1024
-
Reserved
2048
-
Output power
4096
-
Output torque
0+1
+
2
+
4
+
8
=
15
√
F132
Display Items for Stop Mode
0: frequency / function code
1: Keypad jogging
2: Target RPM
4: DC Bus Voltage
8: PID feedback value
16: Temperature
32: Reserved
64: PID given value
128: Reserved
256: Reserved
512: Setting torque
2
+
4
=
6
√
F133
Drive Ratio of Driven System
0.10
~
200.0
1.0
√
F134
Transmission-wheel Radius
0.001
~
1.000
0.001
√
F135
Reserved
F136
Slip Compensation
0
~
10
0
╳
F137
Torque Compensation Mode
0: Linear compensation;
1: Quadratic compensation;
2: User-defined multipoint
compensation
3: Auto torque compensation
3
╳
Summary of Contents for 10G-46-0600-BF
Page 2: ......
Page 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Page 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Page 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Page 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Page 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Page 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Page 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...