14-4
Compliance
AC10 Inverter
Radiated Emissions Profile
EN61800-3 - Limits for electromagnetic radiation disturbance in the frequency band 30 MHz to
1000 MHz
Frequency band
MHz
Category C1
Category C2
Electric field strength
component
Quasi-peak dB(
V/m)
Electric field strength
component
Quasi-peak dB(
V/m)
30
f
230
30
40
230
f
1 000
37
47
NOTE: Measurement distance 10 m.
For category C1, if the field strength measurement at 10 m cannot be made because of high ambient noise
levels or for other reasons, measurement may be made at 3 m. If the 3 m distance is used, the measurement
result obtained shall be normalised to 10 m by subtracting 10 dB from the result. In this case, care should be
taken to avoid near field effects, particularly when the PDS (Power Drive System) is not of an appropriately
small size, and at frequencies near 30 MHz.
When multiple drives are used 3dB attenuation per drive needs to be added.
AC10 EMC COMPLIANCE
Standard EN 61800-3
230V 1PH
Unfiltered
230V 1PH
Filtered
230V 3PH
Unfiltered
230V 3PH
Filtered
400V 3PH
Unfiltered
400V 3PH
Filtered
C
on
du
ct
ed
e
m
is
sion
s
Category C1
Product supplied as a
component, a suitable external
filter is required
Product supplied as a
component, a suitable external
filter is required
Product supplied as a
component, a suitable external
filter is required
Category C2
Product supplied as a
component, a suitable external
filter is required
Product supplied as a
component, a suitable external
filter is required
Product supplied as a
component, a suitable external
filter is required
Category C3
Where I<=100A
When fitted
with an
external filter.
Max cable
length 30
meters
When fitted
with an
internal filter.
Max cable
length 30
meters
When fitted
with an
external filter.
Max cable
length 30
meters
When fitted
with an
internal filter.
Max cable
length 30
meters
When fitted
with an
external filter.
Max cable
length 30
meters
When fitted
with an
internal filter.
Max cable
length 30
meters
R
ad
iat
ed
E
mi
ss
ion
s
Category C3
No specific enclosure required
C
ab
le
R
eq
uire
men
ts
Power
Supply
Cable Type
Unscreened
Segregation
From all other wiring (clean)
Length Limit
Unlimited
Motor Cable
Cable Type
Screened/Armoured
Segregation
From all other wiring (noisy)
Screen to
Earth
Both ends
Max Cable
Length
30 meters
External
Filter to
Drive
Cable Type
Screened/Armoured
Segregation
From all other wiring (noisy)
Length Limit
0.3 meters
Screen to
Earth
Both ends
Summary of Contents for 10G-46-0600-BF
Page 2: ......
Page 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Page 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Page 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Page 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Page 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Page 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Page 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...