1-1
AC10 Inverter
Chapter 1
Introduction
This manual offers an introduction to the installation and connection for the AC10 series.
Parameters setting, software and operation are also covered in this manual.
1.1 Understanding the Product Code
Model Number
The unit is fully identified using a four block alphanumeric code which records how the drive
was calibrated, and its various settings when dispatched from the factory. This can also be
referred to as the Product Code.
Input voltage:
1 : 1 Phase 230V/240V
2 : 3 Phase 230V/240V
4 : 3 Phase 380V/480V
Industry
Rated current
(A):
XXXX
OOO.O
Product model
Frame Size: (mm)
1 :
2:
3:
4:
5:
F : Built in filter
N : without built in filter
10
G
-
1
1
- 0015 - B F
B: Built - in braking unit
80×135×138
106×150×180
138×152×235
156×170×265
205×196×340
6 :
7:
8:
9:
10:
265×235×435
315×234×480
360×265×555
410×300×630
516×326×765
-
-
11:
560×342×910
1.2 Nameplate Example
This example nameplate shows the product as an AC10 series IP20 2.2kW inverter with 3-
phase input.
3Ph: three-phase input; 380-480V, 50/60Hz: input voltage range and rated frequency.
3Ph: 3-phase output; 6.5A, 2.2kW: rated output current and power;
Summary of Contents for 10G-46-0600-BF
Page 2: ......
Page 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Page 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Page 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Page 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Page 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Page 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Page 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...