7-11
AC10 Inverter
7.6.1 Terminal Tightening Torques
Frame Size Power PCB
Terminal
Control PCB
Terminal
Cover
Power Supply,
Motor Terminal
Fan
Fan Cover
Frame 1
1.13Nm
0.6Nm
0.6Nm
1.13Nm
1.3Nm
1.3Nm
Frame 2
1.13Nm
0.6Nm
0.6Nm
1.13Nm
1.3Nm
1.3Nm
Frame 3
1.8Nm
0.6Nm
0.6Nm
1.8Nm
1.3Nm
1.3Nm
Frame 4
2.1Nm
0.6Nm
0.6Nm
2.1Nm
1.3Nm
1.3Nm
Frame 5
3.4Nm
0.6Nm
0.6Nm
3.4Nm
1.3Nm
1.3Nm
Frame 6
4.5Nm
0.6Nm
1.3Nm
4.5Nm
0.9Nm
0.9Nm
Frame 7
10 Nm
0.6Nm
1.3Nm
10 Nm
0.9Nm
0.9Nm
Frame 8
10 Nm
0.6Nm
2.4Nm
10 Nm
0.9Nm
0.9Nm
Frame 9
18 Nm
0.6Nm
2.4Nm
18 Nm
0.9Nm
0.9Nm
Frame 10
18 Nm
0.6Nm
2.4Nm
18 Nm
Big fan 1.5Nm
Small fan 2.4Nm
Frame 11
18 Nm
0.6Nm
2.4Nm
18 Nm
30kW – 180kW Basic Wiring Diagram for Three-phase AC drives (NPN type)
0.2kW – 22kW Basic Wiring Diagram for Multi-stage speed control macro (NPN type)
Summary of Contents for 10G-46-0600-BF
Page 2: ......
Page 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Page 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Page 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Page 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Page 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Page 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Page 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...