background image

Wireless signal generator pure white 
glossy for single mounting 80x80x17mm 
or mounting into the E-Design55 switching 
system. Internal acoustic signal generator 
for a minimum volume of 80 dB. Power 
supply 230 V. Only 0.8 watt standby 
loss. Smart Home sensor.
Up to 24 wireless universal pushbuttons, 
wireless window contacts, window 
handles, smoke detectors FRWB, water 
sensors as well as motion sensors 
FB65B and FBH65SB can be taught in. 

Mounting 

over a 55 mm switch box. 

16 mm over and 33 mm into the box. 
230V power suppl y terminals on the rear.

Startup: 

After power supply is switched on, the 
teach-in mode is activated automatical-
ly for 2 minutes if the memory is empty 
(as-delivered state) or if the teach-in 
mode was not blocked. Teach-in stand-
by is alerted by a short beep.

Teach in wireless pushbutton: 
Universal pushbutton:

 tap briefly 3 times;

Direction pushbutton:

 tap briefly 4 times; 

Doorbell pushbutton:

 tap briefly 5 times.

Wireless window contact:

 Close and 

open the window briefly 3 times;

Wireless window handle sensor FFG7B:

 

(EEP: A5-14-09)

Wireless window/door contact FTKB-hg:

 

(EEP: A5-14-0A)

Wi l

i

FB65B

GB

30 055 068 - 

1

Wireless indoor UP signal  
generator

FIUS55E

Only skilled electricians may install 
this electrical equipment otherwise 
there is the risk of fire or electric 
shock!

Temperature at mounting location: 
-20°C up to +50°C. 
Storage temperature: -25°C up to +70°C.
Relative humidity: 
annual average value <75%.

(EEP: A5 14 0A)

Wireless motion sensor

 

FB65B,  

FBH65SB:

 (EEP: A5-07-01)

Smoke alarm and water sensor:

  

(EEP: A5-30-03)

Wireless water probe FWS81:

 Press 

briefly  the piston slide valve once.

GFVS:

 (EEP: A5-38-08) this automati-

cally switches on confirmation tele-
grams and blocks the teach-in mode.
After a pushbutton is taught in, it is 
 confirmed by a short acoustic signal; 
the teach-in mode is active for a further 
2 minutes. 

To avoid teach-in by accident, the 
 teach-in mode is blocked automatically 
2 minutes after the last teach-in if a 
universal or a direction pushbutton was 
previously taught in. This is alerted by 
two short beeps.

Block teach-in mode immediately: 

Tap the pushbutton under the front 
 panel or an already taught-in direction 
pushbutton 3 times short and once long 
(>2 seconds). Blocking is signalled by 
two beeps.

Unblock teach-in mode: 

Tap the pushbutton under the front panel 
or an already taught-in direction push-
button 4 times short and once long  
(>2 seconds).
Teach-in standby is signalled by a short 
beep. 

Clear memory content completely 
 (restore as-delivered state): 

1.  Switch the power supply off and on.
2.  Tap the pushbutton under the front 

panel or an already taught-in direction 
pushbutton 8 times short and once 
long (>2 seconds).

   Clear is signalled by a short acoustic 

signal.

3.  Apply on 'Teach in wireless push-

button'.   

Switch on/off confirmation telegrams: 

1.  Switch the power supply off and on.
2.  Tap the pushbutton under the front 

panel or an already taught-in direction 
pushbutton 7 times short and once 
long (>2 seconds).

   ON is signalled by two short acoustic 

signals.

   OFF is signalled by a short acoustic 

signal.

Deactivate acoustic signal generator 
for alarm: 

1.  Switch the power supply off and on.
2.  Tap the pushbutton under the front 

panel or an already taught-in direction 
pushbutton 5 times short and once 
long (>2 seconds).

   Deactivation is signalled by two short 

acoustic signals.

Activate acoustic signal generator for 
alarm (as-delivered state): 

1.  Switch the power supply off and on.
2.  Tap the pushbutton under the front 

panel or an already taught-in direction 
pushbutton 6 times short and once 
long (>2 seconds).

   Activation is indicated by a short 

acoustic signal.

Switch on alarm standby: 

(Alarm readiness is always active for 
smoke alarm and water sensors)

 

Press top of direction pushbutton. 

The 

actuator is on alarm standby and 

ON is 

signalled by a triple acoustic signal. If a 
monitored window is open or is opened 
 within 30 seconds after the alarm system 
is enabled, a cyclical signal sounds imme-
diately indicating that the window is open. 
The signal stops immediately the window 
is closed. 

After 30 seconds, 

incoming 

telegrams are evaluated by taught-in 
sensors and the alarm is triggered if ne-
cessary.
After a power failure, the actuator returns 
automatically to alarm standby.
Confirmation telegram: (ORG5) 0x30 = 
alarm standby ON

Switch alarm standby or alarm off: 

Press 

bottom direction pushbutton

 or 

press the pushbutton under the front 
 panel for 10 seconds and then release. 
Alarm standby is switched off and OFF 
is signalled by a short beep.
Confirmation telegram: (ORG5) 0x10 = 
alarm standby OFF

When an alarm occurs, 

a beep sounds 