− App.
13
−
Appendixes
D
Options of the operation through deceleration and stop by turning on Over-travel Inhibit (CWL or
CCWL) (Pr66)
D B
D B
Free run
Free run
D B
Free run
Free run
D B
Clear
0
Pr68
1
2
3
Sequence
at alarm-on (Pr68)
Position
error counter
Operating conditions
During deceleration After stop
D B
Free run
Free run
Free run
0
Pr66
1
DB inhibition at
overtravel limit (Pr66)
Operating conditions
During deceleration After stop
B
Options of the operation through deceleration and stop by turning on Servo-OFF
(Pr69)
C
Options of the operation through deceleration and stop by turning on a protective function (Pr68)
D B
D B
Free run
Free run
D B
D B
Free run
Free run
D B
Free run
Free run
D B
D B
Clear
Hold
Free run
Free run
D B
0
Pr69
1
2
3
4
5
6
7
Sequence
at Servo-OFF (Pr69)
Position
error counter
Operating conditions
During deceleration After stop