− App.
3
−
Appendixes
Peripheral Equipment
Environment
The servo driver should be used under Contamination Level 2 or 1 specified by
IEC60664-1 (housing the driver in an IP54 control box).
Control box
Controller
Insulated power
for interface
Power
Circuit
breaker
Surge
absorber
Noise filter
Noise filter for
signal lines
Protective earth (PE)
L1
U
CN–I/F
CN–SIG
M
RE
V
W
L2
L3
r
t
Noise filter for
signal lines
AC servo
driver
AC servo
motor
Power
100V system: Single-phase 100 to 115V +10%/-15%, 50/60Hz
200V system: Three-phase 200 to 230V +10%/-15%, 50/60Hz
(1) Use under the environment of Over-voltage Category III specified by
IEC60664-1.
(2) The power for interface should be marked CE or EN Standard (EN60950)
type, 12VDC to 24VDC, insulated.
Circuit Breaker
Install a circuit breaker between the power supply and noise filter. The circuit
breaker should be IEC Standard and UL listed marked).
Noise Filter
If several drivers are used, and a single noise filter is installed at the power
supply, consult the manufacturer of the noise filter.
Surge Absorber
Install a surge absorber at the primary side of the noise filter.
<Notes>
When performing a voltage-resisting test, remove the surge absorber. Otherwise
the absorber may be damaged.