− App.
40
−
PrNo.
Parameter Range Unit
Function
description
・You can select the switching between PI and P operations,
and switching between the 1st and 2nd gains.
*1 Switch the PI and P-action with the gain switching
input (GAIN: CN I/F Pin 27).
*2 See Adjustment for the conditions for switching be
tween the 1st and 2nd gains.
・ You can select the conditions for switching between
the 1st and 2nd gains at the position control mode.
30
31
2nd gain
action set-up
Position control
switching mode
0 〜 1
【0】
0 〜 8
【0】
ー
ー
Details of Parameters
Parameters for Switching to 2nd Gains
Value
0
1
Gain selection and switching
Fixed to the 1st gains
*1 (switching between PI and P possible)
Switching between the 1st
and 2nd gains possible *2
GAIN input
COM- disconnected
COM- connected
Operation of the position loop
PI operation
P operation
Value
0
1
2
3
4
5
6
7
8
Conditions for gain switching
Fixed to the 1st gain
Fixed to the 2nd gain
2nd gain selection with the gain switching input (GAIN) ON/
(Pr30 must be set to 1)
2nd gain selection with a larger torque command change
Fixed to the 1st gain
2nd gain selection with a larger velocity command
2nd gain selection with a larger position error
2nd gain selection with the position command issued
2nd gain selection with no in-position