54
−
Parameters
COM+
SRV-ON
SPR/TRQR
GND
ZEROSPD
COM-
7
29
14
15
26
41
DC
12V〜24V
ZEROSPD switch
Close: Run
Open: Stop
One way
operation
For two ways
(CW and CCW)
operation, use a
bipolar power
source.
DC
10V
PrNo.
Pr02
Pr04
Pr06
Pr50
Pr58
Pr59
Pr5A
Parameter description
Control mode set-up
Overtravel input inhibit
ZEROSPD input selection
Velocity command input gain
Acceleration time set-up
Deceleration time set-up
S-shaped accel/decel time set-up
Value
1
1
1
Set as re-
quired
Default
1
1
0
500r/min/V
0
0
0
No.
0
2
3
5
Input signal
Servo-ON
CW overtravel inhibit
CCW overtravel inhibit
Speed zero clamp
Monitor display
+ A
――
――
――
Stop with +A
Trial Run
Wiring Diagram
Run at Velocity Control Mode
①Apply a DC voltage between the velocity command input SPR (CN I/F pin 14) and GND (CN
I/F pin 15). Increase the voltage gradually from 0, and make sure that the motor runs and
the speed change accordingly.
②Select the Monitor Mode to monitor the motor speed.
・Make sure that the motor speed is as per the commanded speed.
・Set the command to 0 to see if the motor stops.
③If the motor still runs at very low speed, even the command voltage is set to 0, use the
Auxiliary Mode to correct the voltage of command input (see Automatic Offset Adjustment
function in Appendix).
④To change the speed or direction, adjust the following parameters.
Pr50 (Velocity Command Input Gain)
Pr51 (Velocity Command Input Inversion)
See "Details of Parameters" in Appendix
Input Signal Status
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com