− App.
64
−
Details of Parameters (Auxiliary Function Mode)
Auxiliary Function Mode
Operation
Automatic Offset Adjustment Mode
This mode is to set the voltage of analogue velocity (or torque) commands to 0V, measure
the offset during Servo-OFF, and correct the offset so that small motions (rotation) can be
eliminated. This automatic offset adjustment mode should be started by the following proce-
dure.
Procedure
① Select the automatic offset adjustment mode using the procedure mentioned above.
will appear. Press SET button to display
② The mode is ready for
execution.
Automatic offset adjustment
mode
Motor trial mode
Alarm clear mode
Absolute encoder clear mode
SET
Keep pressing UP but-
t o n ( f o r a b o u t t h r e e
seconds). The number of
short bars (-) will increase.
The mode is started.
The adjustment will
complete instantaneously.
Adjustment completed
Error
SET
Press UP or DOWN to select your desired mode.
Mode selection
Execution