− App.
30
−
Details of Parameters
Parameters for Function Selection
Default setting is shown by [ ]
PrNo.
Parameter
Value
Function
If multiple axes are used, it is necessary for the river to identify
the current axis that is accessed by the host (e.g. PC). You
can identify axis address by number with this parameter.
You can select the type of information to be displayed initially
on the 7-segment LED at power on.
00
01
Axis address
Initial LED
status
0 〜
15
【1】
0 〜 2
・With the mains power ON, the current
value of RSW ID (0 to F) on the LED
touch panel is downloaded to the driver
as the value of this parameter.
・The value of this parameter cannot be
modified by other means than the rotary
switch (RSW) ID.
Reading (pulse count) of the
position error counter
Unit: pulse
+:generates
CCW-torque
−:generates
CW-torque
Motor speed
Unit: r/min.
+:runs in CCW
−: runs in CW
Motor torque
Unit: %
+:generates
CCW-torque
−:generates
CW-torque
ID
MODE
IM
SP
G
SET
Power ON
Pr01 value
0
1
2
Flashes (about two
seconds) during the
initializing process
【1】
Displayed
informatio
n
Polarit
y