72
−
Maintenance and Inspections
Replacement Guidance
Parts replacement cycles depend on the actual operating conditions and how the
equipment has been used. Defective parts should be replaced or repaired immediately.
Equipment
Driver
Motor
Part
Smoothing condenser
Cooling fan
Aluminum elec-
trolytic capaci-
tor on the print
board
Bearing
Oil seal
Encoder
Battery
(Absolute encoder)
Standard replacement
cycles (hour)
about 5 years
2 to 3 years
(10 to 30 thousand hours)
about 5 years
3 to 5 years
(20 to 30 thousand hours)
5000 hours
3 to 5 years
(20 to 30 thousand hours)
1 year from
the first use
Remarks
The replacement cycles shown here
are just only for reference. If any part
is found defective regardless of the
standard replacement cycles, im-
mediately replace it with a new one.
Prohibited
Dismantling for inspections or repairs should be done by our
company (or our sales agents).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com