− App.
33
−
Appendixes
PrNo.
Parameter
Value
Function
05
Internal speed
switching
0 〜 2
【0】
・You can select whether to enable or disable the internal velocity set-up.
・There are four options of internal velocity commands: Pr53 (1st speed),
Pr54 (2nd speed), Pr55 (3rd speed) and Pr56 (4th speed).
・Block diagrams of the internal and external velocity set-up functions
A
INH (CN I/F Pin 33): Internal velocity command select 1
B
CL (CN I/F Pin 30): Internal velocity command select 2
・You can easily set-up the internal speed with
contact inputs only.
0
External velocity command
↑
↑
↑
1
1st Internal speed (Pr53)
2st Internal speed (Pr54)
3st Internal speed (Pr55)
4st Internal speed (Pr56)
2
←
←
←
External velocity command
Value of Pr05
30
33
AD
converter
1
1
2
2
0
0
Pr05
SPR
CL
CN I/F
INH
External velocity
command
Contact
input
Velocity
command
1st.Internal speed (Pr53)
2st.Internal speed (Pr54)
3st.Internal speed (Pr55)
4st.Internal speed (Pr56)
14
INH
(Pin 33)
Off
On
Off
On
CL
(Pin 30)
Off
Off
On
On
・ Switching between the four options of internal velocity commands uses two contact inputs.Example:
4-speed operation using the internal velocity commands To run/stop the motor, you need zero speed
clamp input(ZEROSPD) and Servo-ON input(SRV-ON) in addition to CL/INH input.