− App.
34
−
Details of Parameters
PrNo.
Parameter
Value
Function
You can switch whether to enable or disable the zero
speed clamp input (ZEROSPD, CN I/F Pin 26).
05
06
Internal speed
switching
ZEROSPD
input
selection
0 〜 1
【0】
Function of ZEROSPD input (Pin 26)
The ZEROSPD input is disabled, and the driver assumes that
the motor is always "not clamped to zero speed".
The ZEROSPD input is enabled, and the velocity command is
regarded as "0", by opening the connection to COM- .
Value
0
1
・ Example: 4-speed operation using the internal velocity commands
To run/stop the motor, you need zero speed clamp input(ZEROSPD) and
Servo-ON input(SRV-ON) in addition to CL/INH input.
< Notes >
You can set-up the acceleration/deceleration time, and S-curve acceleration/
deceleration time individually with parameters.
See the following descriptions of the parameters:
Pr58 (Acceleration time set-up)
Pr59 (Deceleration time set-up)
Pr5A (S-shaped accel/decel time set-up)
SER-ON input
Servo-On
Operation
Stop
Velocity
Off
Off
1st speed
2nd speed
3rd speed
4th speed
Time
Off
On
On
On
On
Off
ZEROSPD input
INH input
CL input
(continued)