− App.
61
−
Appendixes
Viewing the causes and history of an alarm
・
You can view the latest 14 alarms including the current one.
Alarm Code No. (if no errors are occurring, -- is displayed)
:Current alarm
:No.0 alarm (the latest (current) alarm)
:No.1 alarm
:No.13 alarm (the oldest alarm)
・
To select any alarm event you wanted, press UP or DOWN button for access to the
desired alarm No.
( Pressing DOWN will move to older alarms.)
<Notes>
1.If an alarm which is stored in the history memory is occurring, the alarm is given E-0 (Error-0).
2.The alarm history cannot be deleted.
Alarm Numbers and Functions
•••
Alarm
Code No.
11
12
13
14
15
16
18
20
21
22
23
24
25
26
Function
Undervoltage, control power
Overvoltage
Undervoltage, main power
Overcurrent
Overheat
Overload
Regenerative discharge
Encoder A/B phase error
Encoder communication error
Encoder connection error
Encoder communication data error
Position error
Hybrid error
Overspeed
Alarm
Code No
.
27
28
29
35
36
37
38
40
41
42
44
45
47
Other than the above
Function
Command pulse saler error
External scale error
Error counter over flow
External scale disconnection error
EEPROM parameter error
EEPROM check code error
Overtravel inhibit input error
Absolute system down error
Absolute counter over flow error
Absolute over-speed error
Absolute single-turn counter error
Absolute multi-turn counter error
Absolute status error
Other errors