5-4
Troubleshooting
F
AULT
S
YMPTOM
C
ODES
(FSC)
0501
Barcode Comm. Error
Enter to Reboot or
Power Down to Clear
HARD fault - Unable to open the barcode serial
port. The loopback test of the baud rate divisor reg-
isters or one of the "expected 0" bit tests failed. It is
not necessary that a bar code scanner be connected
for this fault to be reported.
C, D, G
0601
Clock Init. Error
Enter to Reboot or
Power Down to Clear
HARD fault - the real time clock chip would not
initialize (never reported in any library/loader code)
C, D, G
0602
LP-RAM Init. Error
Enter to Reboot or
Power Down to Clear
HARD fault - the low power RAM failed the integrity
test prior to initialization.
C, D, G
0603
Clock Download Error
Press Enter to Clear
SOFT fault - The initialization of the real time clock via
the trace serial port failed.
F
0701
Slv. Comm Open Error
Enter to Reboot or
Power Down to Clear
HARD fault - Unable to open the barcode serial port.
The loopback test of the baud rate divisor registers or
one of the "expected 0" bit tests failed.
C, D, G
0801
Not In Br. Menu Mode
Press Enter to Clear
SOFT fault - A command sequence error was
detected. The Web TLC must command the library to
"menu mode" before it will accept most commands.
This is an automatic feature of the Web TLC code.
F
0802
Invalid Novram Upd.
Press Enter to Clear
SOFT fault - the Web TLC command to update the
novram contained an unrecognized post update
action. The novram has been updated but the extra
action has not occurred.
F
0803
Executing Immed. Cmd
Press Enter to Clear
SOFT fault - The loader was completing an immediate
command when a new browser (Web TLC) request
was made. The new request has been rejected.
F
1001
SCSI Firmware Error
Press Enter to Clear
SOFT fault - an internal firmware error has been
detected in the SCSI process.
F
1002
SCSI FIFO Empty
Press Enter to Clear
SOFT fault - the SCSI controller chip FIFO was empty
when it was expected to contain command bytes.
F
1003
SCSI FIFO Error
Press Enter to Clear
SOFT fault - the SCSI controller chip FIFO still contained
after all of the expected bytes were read.
F
1004
SCSI Gross Error
Press Enter to Clear
SOFT fault - the SCSI controller chip has reported a
major err in its status register.
F
1005
Illegal SCSI Cnt Cmd
Press Enter to Clear
SOFT fault - the SCSI controller chip has reported an
illegal command from the host.
F
Table 0–1 Fault Symptom Codes
Summary of Contents for LoaderXpress
Page 1: ...Part No 104249 102 04 2004...
Page 3: ......
Page 5: ...xii...
Page 6: ...xiii...
Page 12: ...1 6...
Page 16: ...2...
Page 22: ...1 6 Introduction TAPE CARTRIDGE MAGAZINES...
Page 50: ...2 28 Installation CONFIGURATION OPTIONS DESCRIPTIONS...
Page 98: ...5 20 Troubleshooting USING THE DEMO SUBMENU...