2-10
Installation
R
ACK
M
OUNT
I
NSTALLATION
(I
F
APPLICABLE
)
CAUTION:
Rack mounted units are installed from the bottom due to the weight of
the unit when fully extended. An installed unit with empty spaces below that is fully
extended may cause the rack to tip forward or cause personal injury. It is
recommended that two persons support and slide the unit in the rack.
1) Locate the screw holes in the front and rear rails of the cabinet or equipment rack
where the library slides are to be installed.
Figure 2–13 Mounting Screw Locations
Figure 2–14 Rack Slide Mounting Holes
2) Locate the proper position (three holes above the top of the outer slide position)
for one clip nut behind the upper hole in each panel extension and the install 10-
32 clip nuts.
1 U is measured from the
center of one ½ inch space
to the center of the
next ½ inch space.
The Overland LoaderXpress
uses 4 U of rack space.
Hole spacing = 5/8 inch
1 U = 1.75 inches
Hole spacing = ½ inch
Hole spacing = ½ inch
Hole spacing = ½ inch
Hole spacing = 5/8 inch
Hole spacing = 5/8 inch
Hole spacing = 5/8 inch
Hole spacing = 5/8 inch
Hole spacing = 5/8 inch
1 U = 1.75 inches
Location of rails and
mounting hardware
for the LoaderXpress
Nut Clips
Slide rails and
Mounting Screws
4 U for
LoaderXpress
LXL-0069
Summary of Contents for LoaderXpress
Page 1: ...Part No 104249 102 04 2004...
Page 3: ......
Page 5: ...xii...
Page 6: ...xiii...
Page 12: ...1 6...
Page 16: ...2...
Page 22: ...1 6 Introduction TAPE CARTRIDGE MAGAZINES...
Page 50: ...2 28 Installation CONFIGURATION OPTIONS DESCRIPTIONS...
Page 98: ...5 20 Troubleshooting USING THE DEMO SUBMENU...