3-6
Se
ct
io
n3
APPLICATION and
SETTING EXAMPLES
ZS-HL
User’s Manual
Section3
Measuring the Vertex 2 (peak) in the Line Beam
Measuring the Vertex 2 (peak) in the Line Beam
The following describes the setting procedure for measuring a small vertex.
1.
Set the mode switch to FUN.
2.
Select [ON] in [SYSTEM]-[MULTI-
TASK].
The confirmation message is
displayed. Select [OK].
Setting peak (TASK1)
3.
Press the MENU key to display the
TOP menu.
4.
Press the ESC key to display the
TASK switching menu, and select
[TASK1].
5.
Select [PEAK] in [MEASURE]-
[TASKSET].
Peak
Line beam
FUN
RUN
TEACH
1
OFF
2
ON
1
SENSING
2
MEASURE
3
FILTER
1
T A S K 1
2
T A S K 2
3
T A S K 3
4
T A S K 4
1
OFF
2
AVERAGE
3
PEAK