6-4
Section6
I/
O
ZS-HL
User’s Manual
Section6
Settings for Linear Output
Setting Focus
For the linear output, because the measured value is converted to a current of 4 to 20 mA
or a voltage of -10 to +10, and is then output, you can freely set the relationship between
the displayed measured value and output value. Match the settings to suit the connected
external device.
Enter the output values for any two current values or voltage values to set the output
range. (default value: OFF)
X
Example: Set 0 mm to 4 mA and 5 mm to 20 mA. (for current output)
Separate the two specified points by at least 1 % of the rated measurement range for the connected
Sensor Head or 40µm or longer.
Example: For the ZS-HLDS5T (diffuse reflection type)
The two measured points must be separated by at least “10 mm × 0.01 = 0.1 mm” as the measuring
range is “±5 mm (10 mm)”.
X
FUN mode-[I/O SET]-[ANALOG]-[FOCUS]-[ON]
1.
Set the output value (voltage or current
value) of point 1.
The output value is displayed on the main
display.
2.
Press the SET Key to apply the setting.
3.
Set the measured value for point 1.
The measured value is displayed on the sub-
display.
4.
Press the SET Key to apply the setting.
5
4
0
20
0
5
4
0
20
-5
-5
Output current
(mA)
Measured value
(mm)
Output current
(mA)
Measured value
(mm)
INPUT POINT 1
CHANGE SET:OK
INPUT POINT 1
VAL SET:OK
DIG
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...