6-18
Section6
I/
O
ZS-HL
User’s Manual
Section6
Timing Charts
Timing Charts
The following shows the timing charts when communication is performed with external
devices.
The parts in which specific values are stated in the timing chart are the times that do not
depend on the sampling cycle.
■
Basic Operation
Item
Minimum
Average
Maximum
Remarks
T1
Time during which the mea-
sured value is determined
from the laser beam emis-
sion
–
–
Sampling
cycle × 3
When the measure-
ment is performed con-
tinuously and the
amount of light is stable
T8
Update cycle of judgment
output
Sampling cycle
T9
Update cycle of terminal
block output
Sampling cycle × update cycle
The update cycle can
be set in [I/O SET]-
[TERMINAL]-[CYCLE].
T10 OFF time of GATE signal
68 µs
T21 Response time of GATE
signal
320 µs
T11 Response time of linear
output
–
–
500 µs
It changes depending
on the way the mea-
sured value fluctuates.
ON
ON
OFF
OFF
Laser beam emission
Internal processing
Judgment output
Terminal block output
T11
T10
T21
T9
T8
a
a
b
b
b
a
T1
Linear output
GATE signal
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...