Sect
ion5
SETTINGS FOR
FUNCTIONS
Section5
Setting the Filter Function
5-13
ZS-HL
User’s Manual
Setting AVERAGE
The average of the measured values obtained based on the preset number of samples
can be output. Select this setting when you want to ignore sudden changes in measured
values.
X
FUN Mode-[FILTER]-[AVERAGE]
Setting Differentiation
Use the differentiation function to detect only sudden changes in the measured values that
occur during very short periods of time.
The differentiation function detects changes between the present value and the measured
value that is in effect just before the comparing pitch. The coefficient of this comparing
pitch is defined as the differentiation cycle.
Example: Differentiation cycle=10 ms
X
FUN Mode-[FILTER]-[DIFF]
Setting
Description
1, 2, 4, 8, 16, 32, 64, 128, 256, 512,
1024, 2048, 4096
(When the mode is set to High-
Speed mode, the value is from 1 to
256.)
Sets the average count. (default value: 128)
Setting
Description
OFF
The differentiation function is not used. (default value)
ON
Sets the cycle (ms) in which to perform differentiation.
Range: 1 to 500
Present value
Sampling
Comparison interval 10 ms
Display value
(differentiation result)
Sampling cycle
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...