4-8
Sec
tion4
FUNC
TION
S AN
D OPERA
T
ION
S
USED
DU
RING OPERA
T
ION
ZS-HL
User’s Manual
Section4
Threshold Setting
■
TEACHING
Performs measurement and uses the measurement results to set threshold values.
Teaching is useful when threshold samples, i.e., with the upper and lower limits, can be
obtained beforehand.
Hold, trigger, and scaling settings that have been made before teaching are reflected in
the teaching measurements.
The following describes the operation method using the procedure for setting the HIGH
threshold value as an example.
1.
Set the mode switch to TEACH.
2.
Switch the threshold switch to “H” to
set the HIGH threshold value.
3.
Set the workpiece.
4.
Press the MENU key to apply the set-
ting.
The applied threshold value will be
displayed on the sub-display.
Sensor Head
Sensor Head
Teaching point
= HIGH threshold value
Teaching point
= LOW threshold value
Threshold sample (lower limit)
Threshold sample (upper limit)
TEACH
RUN
L
1
2
MENU
ESC
SET
3
4
FUN
H
TEACH
RUN
FUN
TEACH
RUN
L
1
2
MENU
ESC
SET
3
4
FUN
H
L
H
TEACHMODE
MENU: TEACHING
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...