Se
ct
io
n 1
FEATURES
Section 1
System Configuration
1-3
ZS-HL
User’s Manual
System Configuration
In addition to operations with the basic configuration, ZS-HLDC can support various
measurement applications when combined with numerous peripheral devices.
H
LD ON ZERO ENABLE
P
L
RUN
RUN
ZS-RPD
P
ARALLEL
OUTPUT
UNIT
RS-232C
DA
T
A
ZS-HLDS_ _ _/LD_ _
Detects a sensing object.
ZS-HLDC_ _
Performs measurements
and outputs the results.
ZS-XC_A (1 m, 4 m, 8 m)
ZS-XC_ _B(5 m, 10 m): Up to two cables can be connected.
ZS-XC5BR (5 m): Up to two cables can be connected.
Robot cable type.
DC24 V (±10 %)
Recommended part
(1) If the number of connections is
1: S82K-01524 (DC24 V, 0.6 A)
(2) If the number of connections is
2 to 3: S82K-05024 (DC24 V, 2.1 A)
(3) If the number of connections is
4 to 10: Prepare as many of the
above power supplies of (1) and
(2) as you need.
(*1)
Sensor Head
Sensor Controller
Power supply
(Setting support software for personal computers)
This setting support software sets
sensing conditions while monitoring
the receiving status, and allows a user
to check the measured value in a time
series graph.
*1
: Accessory for the Sensor Controller ZS-HLDC_1A
(*1)
USB
Peripheral devices
Personal computer
Programmable controller
Programmable terminal
High-speed input board (personal computer)
• Communication using commands
• Communication using SmartMonitor
ZS Professional
• Communication using commands
• Communication using NS SmartMonitor
• Compare waveforms and make a judgment
• Obtain measurement data quickly
USB
RS-232C
RS-232C
Linear output
Real-time parallel
Output unit
ZS-RPD_1
Extension cable for Sensor Head
Long Extend the cable of Sensor Head
ZS-XPT2
ZS-XPT2
Digital panel meter
SmartMonitor ZS
• Digital equalizer ZS-XEQ (*2)
Method of connecting
a cable
High-speed parallel
output
*2:
Only the ZS-HLDS
@@@
Sensor Head can be connected to the ZS-XC
@@
CR,
ZS-XC02D, and ZS-XEQ.
Basic configuration
• Digital equalizer
connection cable
ZS-XC02D (*2)
• Extension cable for a long
distance (*2)
ZS-XC_ _CR (15 m, 25 m)
p.2-6
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...