background image

INTERIORLIGHT

See Note 9.0

(See Table Pg 3.

7.1 & 7.3)

Refer to Selective Unlocking

See note 1.6

Negative out when armed.

Can be connected to Pager Module/Tracking

System. To select this function see

Table 1 and note 5.0

See Note 6.0

Requires additional Window Closer Module

(PFK Part No. 210-000)

To select this function see 3.1 & Table 1.

Wiring information will

be supplied with the Module

TURBO RUN ON

SELECTIVE UNLOCKING

THE 2 OUTPUTS BELOW ARE NEGATIVE SWITCHING (MAXIMUM CURRENT 300mA)

THE  OUTPUT BELOW IS  NEGATIVE SWITCHING

(MAXIMUM CURRENT 300mA)

FUSE

NOTE :
FUSES
ARE NOT
SUPPLIED

+12V WHEN THE IGNITION IS IN
THE ON AND CRANK POSITION.

SEE ALTERNATE DIAGRAM BELOW.

NOTE : DO NOT CONNECT WHEN
TURBO RUN ON IS USED.

IGNITION (FUSED)

OR

OR

OR

PAGE

1 OF 4

NO HIJACK ON POSITIVE DOOR INPUT

BLACK

BLACK/GREY

DRIVER'S

DOOR SWITCH

HIJACK CANCEL

(UNDER CARPET SWITCH)

ALSO USED AS AN EMERGENCY

CANCEL FOR TURBO RUN ON

DIODE

(3 AMP)

DOORS

DOORS

WIRE HARNESS
INTO THE VEHICLE
PRIOR TO PLUGGING
CONTROL MODULE IN

ANTENNA

Do not sleeve or tape antenna

with other wires. Run antenna

separately and try to position

away from metallic objects

RED

+ 12 VOLTS

RED

INDICATOR
+ 12 VOLTS

WHITE

SPEAKER

OUTPUT

CHASSIS

WHITE

RED

BLACK/WHITE

RIPCORD

+ 12 VOLTS

SEE

NOTE

1.4

GROUND

GROUND

BOOT

BONNET

ANTI HIJACK (OPTIONAL)

CENTRAL LOCKING

SIREN/HORN OPTIONS

WIRE THE HIJACK DOOR WIRE AS SHOWN (DIODE FITTED OPTIONALLY TO
ISOLATE DRIVERS DOOR) AND FIT THE UNDER CARPET CANCELLATION
SWITCH IN A WELL CONCEALED BUT ACCESSIBLE LOCATION TO ENABLE
THE HIJACK TO BE CANCELLED

TO SELECT THE HIJACK OPTION - SEE NOTE 4.0

}

CHASSIS

+ 12 V

BROWN WIRE

BROWN/WHITE

UNLOCK (NEGATIVE PULSE)

LOCK  (NEGATIVE PULSE)

BLACK/

YELLOW

BLUE/GREY

BLUE/GREY

GREEN

GROMMET

Common

Coil
Coil

N.Closed

N.Open

+12V

+12V

Connect to "BLUE" Door wire

RELAY REQUIRED
FOR POSITIVE
INTERIOR LIGHT.
WITH POSITIVE
DOOR SWITCHING
INTERIOR LIGHT
WILL NOT FADE
ON AND OFF

INTERIOR

LIGHT

See Note 9.0

Not connected

RELA

Y

30

85

86

87a

87

+ 12 V

To ground or +12V as required

Not connected

Not connected

Cut

ignition

NEW

switched

ignition

to vehicle

Ignition

switch

Ignition

switch

+12V

+12V

+12V Battery

Common

Common

Coil

Coil

Coil

Coil

N.Closed

N.Closed

N.Open

N.Open

TO TRUNK RELEASE SOLENOID

(PFK SOLENOID - PART NO. 088-510)

TRUNK RELEASE

RELA

Y

RELA

Y

30

30

85

85

86

86

87a

87a

87

87

G.P. RELAY Part No. 436-900 (NOT SUPPLIED)

NOT

SUPPLIED

G.P

. RELA

Y

Part No. 436-900

NOT

SUPPLIED

G.P

. RELA

Y

Part No. 436-900

NB : The 436-900 is rated

for 25amp continuous ONLY.

Confirm current output, if a

higher capacity is required, fit

a relay with sufficient rating.

CENTRAL LOCKING CONTROL

(0.5 AMP MAXIMUM)

TO EXTEND PULSE DURATION FOR

VACUUM PUMPS     SEE NOTE 1.5

FOR CONFIGURATIONS OTHER THAN

NEGATIVE, USE THE UNIVERSAL

CENTRAL LOCKING INTERFACE - (CI 65)

PFK PART No. 065-005     SEE NOTE 1.5

WHITE

POSITIVE

DOORS

GREY

CANCEL

DPFK 457/520

CIRCUIT 2

CIRCUIT 2

CIRCUIT 1

CIRCUIT 1

CUT CIRCUIT TO BE
IMMOBILISED AND
REJOIN VIA CIRCUIT 2
(20 AMP CAPABILITY)
SEE NOTE 1.1

CUT CIRCUIT TO BE IMMOBILISED
AND REJOIN VIA CIRCUIT 1
(20 AMP CAPABILITY) SEE NOTE 1.1

SIREN  + 12 V

OR

OR

JOIN TO THE

POSITIVE

WIRE OF

INDICATOR

LIGHTS

+

LEFT

+

RIGHT

YELLOW

INDICATOR

YELLOW

INDICATOR

HOTWIRE OPTION

CONNECT TO LOAD SIDE OF
IMMOBILISER CIRCUIT
(See Note 1.3)

VIOLET

NEGATIVE

BONNET

BLUE

NEGATIVE

BOOT

PINK

NEGATIVE

DOOR

GREEN

IGNITION

See Note 8.0

See Table

E. 6.1 & 6.2

HORN SPEAKER   PFK No. 076-800

See Table D. 6.1 - 6.6

See Table

E. 6.4 - 6.6

1. Do not connect across a 12V supply.
2. Do not cut the horn speaker cable

with the supply lead connected.

OR

WINDOWS

PAGER/TRACKING

OR

WHITE/

BLACK

WHITE/

BLACK

CONNECT TO THE NEGATIVE FACTORY

HORN RELAY TRIGGER WIRE OR THE

NEGATIVE

RELAY TRIGGER WIRE

SIREN

(

(

+12V

TYPICAL CAR HORN

CONFIGURATION

85

87A

87

86

30

12V

VEHICLE HORN

GROUND

AUTOWATCH 457 Rli ALARM/IMMOBILISER WIRING DIAGRAM

1.
2.
3.
4.
5.
6.

7.
8.
9.

10.

11.

12.

13.
14.
15.
16.
17.
18.

Ignition (Green Label)
Neg. Bonnet (Blue Label)
Hijack Disable (Grey Label)
Ground (Black Label)
Ground (Black Label)
Unlock (Brown/white wire)

Aux 2 (Windows/Pager) (Black/white wire)
Aux 1 (Selective Unlock / Neg. Out when armed) (Black/yellow wire)
+ 12V (Red Label)
Speaker / Siren / Horn (White Label)
Ne Hijack Doors + Dome Light driving (Pink Label)
Negative Boot (Violet Label)

Hotwire / Brake input / Positive Doors (White Label)
Aux 3 (Trunk release / Turbo-run on) (Blue/grey wire)
Lock (Brown wire)
Ind12V (Red Label)
Indicator (Yellow Label)
Indicator (Yellow Label)

REAR VIEW

OF

18-WAY

HARNESS

{

BLACK

BLACK

WHITE

SPEAKER

OUTPUT

WHITE

SPEAKER

OUTPUT

CIRCUIT 3 IMMOBILISATION.

Use the Power Line Comms

Immobiliser (See Note 1.1 & Pg 4.

For wiring & installation)

REV. 3

28/06/07

For Hazard

Pulse Feature

See Note 14.0

& Table 8.9

*

For Hazard Pulse Feature

See Note 14.0 & Table 8.9

*

NB : If negative

Hazard Pulsing is

required connect

to ground.

Summary of Contents for 457 Rli

Page 1: ...30 85 85 86 86 87a 87a 87 87 G P RELAY Part No 436 900 NOT SUPPLIED NOT SUPPLIED G P RELAY Part No 436 900 NOT SUPPLIED G P RELAY Part No 436 900 NB The 436 900 is rated for 25amp continuous ONLY Confirm current output if a higher capacity is required fit a relay with sufficient rating CENTRAL LOCKING CONTROL 0 5 AMP MAXIMUM TO EXTEND PULSE DURATION FOR VACUUM PUMPS SEE NOTE 1 5 FOR CONFIGURATIONS...

Page 2: ...YOU WILL NEED TO ALTER A FEW WIRES TO ACCOMMODATE THE ADDITIONAL FEATURES CROSS REFERENCE THE 276RLi OR 446RLi DIAGRAMS TO THE DIAGRAM TO SEE THE VARIATION IN WIRING MECHANICAL INSTALLATION MOUNTING The control module must be installed in a concealed location inside the vehicle Do not plug in the control module until the wiring is complete All wire joints must be soldered and well insulated Mount ...

Page 3: ...must be fitted as an emergency override even if the hijack option is not selected 457 RLi FEATURE SELECTION TABLE NOTE THE PROGRAMMING SELECTION CODES WHERE APPLICABLE ARE THE SAME AS THE 446RLi BUT DIFFER FROM THE 436RLi OPTION FEATURE Trigger Report back See 11 0 Hijack Selection See 4 0 Hijack Time Selection See 4 0 Unlock with Ignition Lock with Ignition Window Pager See 5 0 Interior Dome Ligh...

Page 4: ...T PASSENGER DOOR MOTOR PASSENGER AND REAR DOOR MOTORS REAR PASSENGER DOOR MOTORS THIS CONFIGURATION IS IDEAL FOR MODIFYING FACTORY FITTED CENTRAL LOCKING MOTORS FLEX BROWN WHITE 12 VOLTS FUSED 20A GREY BROWN VIOLET YELLOW C I 6 5 ALTERNATING POLARITY CENTRAL LOCK MODULE KIT A L A R M U N I T BRN WHT UNLOCK BROWN LOCK JOIN TO CORRESPONDING CONTROL WIRES FROM ALARM CENTRAL LOCKING INPUT CONTROL CONN...

Reviews: