10
-20
C3-01 Slip compensation gain
1.0
*3
d3-01
Jump frequency 1
0.0
C3-02
Slip compensation primary delay
time
200
*2
d3-02
Jump frequency 2
0.0
C3-03 Slip compensation limit
200
d3-03
Jump frequency 3
0.0
C3-04
Slip compensation selection during
regeneration
0
d3-04
Jump frequency width
1.0
C3-05
Output voltage limit operation
selection
0
d4-01
Frequency reference hold function
selection
0
C4-01 Torque compensation gain
1.00
d4-02
+ - Speed limits
10
C4-02
Torque compensation primary
delay time constant
20
*2*3
d5-01
Torque control selection
0
C4-03 Forward starting torque
0.0
d5-02
Torque reference delay time
0
C4-04 Reverse starting torque
0.0
d5-03
Speed limit selection
1
C4-05 Starting torque time constant
10
d5-04
Speed limit
0
C5-01 ASR proportional gain 1
20.00
d5-05
Speed limit bias
10
C5-02 ASR integral (I) time 1
0.500
d5-06
Speed/torque control switching
timer
0
C5-03 ASR proportional gain 2
20.00
d6-01
Field weakening level
80
C5-04 ASR integral (I) time 2
0.500
d6-02
Field frequency
0.0
C5-05 ASR limit
5.0
d6-03
Field forcing function selection
0
C5-06 ASR primary delay time
0.004
d6-05
A
φ
R time constant
1.00
C5-07 ASR switching frequency
0.0
E1-01
Input voltage setting
200
*7
C5-08 ASR integral (I) limit
400
E1-03
V/f pattern selection
F
C6-02 Carrier frequency selection
6
*6
E1-04
Max. output frequency
60.0
C6-03 Carrier Frequency Upper Limit
15.0
*6
E1-05
Max. voltage
200.0
*2
*7
C6-04 Carrier Frequency Lower Limit
15.0
*6
E1-06
Base frequency
60.0
*2
C6-05
Carrier Frequency Proportional
Gain
00
E1-07
Mid. output frequency
3.0
*2
C6-11
Carrier frequency for open-loop
vector control 2
4
E1-08
Mid. output frequency voltage
15.0
*2
*7
d1-01
Frequency reference 1
0.00
E1-09
Min. output frequency
1.5
*2
d1-02
Frequency reference 2
0.00
E1-10
Min. output frequency voltage
9.0
*2 *7
d1-03
Frequency reference 3
0.00
E1-11
Mid. output frequency 2
0.0
*9
d1-04
Frequency reference 4
0.00
E1-12
Mid. output frequency voltage 2
0.0
*9
d1-05
Frequency reference 5
0.00
E1-13
Base voltage
0.0
*10
d1-06
Frequency reference 6
0.00
E2-01
Motor rated current
1.90
*6
d1-07
Frequency reference 7
0.00
E2-02
Motor rated slip
2.90
*6
d1-08
Frequency reference 8
0.00
E2-03
Motor no-load current
1.20
*6
d1-09
Frequency reference 9
0.00
E2-04
Number of motor poles
4
d1-10
Frequency reference 10
0.00
E2-05
Motor line-to-line resistance
9.842
*6
d1-11
Frequency reference 11
0.00
E2-06
Motor leak inductance
18.2
*6
d1-12
Frequency reference 12
0.00
E2-07
Motor iron saturation coefficient 1
0.50
d1-13
Frequency reference 13
0.00
E2-08
Motor iron saturation coefficient 2
0.75
d1-14
Frequency reference 14
0.00
E2-09
Motor mechanical loss
0.0
d1-15
Frequency reference 15
0.00
E2-10
Motor iron loss for torque compen-
sation
14
*4
d1-16
Frequency reference 16
0.00
E2-11
Motor rated output
0.40
*4
d1-17
Jog frequency reference
6.00
E3-01
Motor 2 control method selection
2
d2-01
Frequency reference upper limit
100.0
E3-02
Motor 2 max. output frequency
(FMAX)
60.0
*2
d2-02
Frequency reference lower limit
0.0
E3-03
Motor 2 max. voltage (VMAX)
200.0
*2
d2-03
Master speed reference lower limit
0.0
E3-04
Motor 2 max. voltage frequency
(FA)
60.0
Table 10.5 User Constants (Continued)
No.
Name
Fac-
tory
Setting
Set-
ting
No.
Name
Fac-
tory
Setting
Set-
ting