User Constants
10-
23
* 1. Not initialized. (Japanese standard specifications: A1-01 = 1, A1-02 = 2)
* 2. The factory setting will change if the control method is changed. The factory settings given above are for V/f without PG control.
* 3. Factory setting depends on the control method (A1-02).
* 4. For V/f with PG control: 1.0
* 5. For Inverters with a capacity of 55 kW or more: 2.00
* 6. Setting range and initial setting depend on Inverter capacity.
* 7. Setting for 200 V class Inverters. For 400 V class Inverters, double the value.
* 8. Factory setting in the parentheses is for 3-wire sequence.
* 9. The contents is ignored if the setting is 0.0.
* 10.E1-13 will have the same value as E1-05 after autotuning.
* 11.If the set value is 0, acceleration will be to the speeds for the acceleration times (C1-01 to C1-08)
* 12.The setting range is 10% to 200% of the Inverter rated output. (The value given is for a 200 V Class Inverter for 0.4 kW.)
L8-18
Soft CLA selection
1
o2-01
LOCAL/REMOTE key enable/dis-
able
1
N1-01
Hunting-prevention function selec-
tion
1
o2-02
STOP key during control circuit
terminal operation
1
N1-02 Hunting-prevention gain
1.00
o2-03
User constant initial value
0
N2-01
Speed feedback detection control
(AFR) gain
1.00
o2-04
kVA selection
0
*6
N2-02
Speed feedback detection control
(AFR) time constant
50
o2-05
Frequency reference setting
method selection
0
N2-03
Speed feedback detection control
(AFR) time constant 2
750
o2-06
Operation selection when digital
operator is disconnected
0
N3-01
High-slip braking deceleration fre-
quency width
5
o2-07
Cumulative operation time setting
0
N3-02 High-slip braking current limit
150
o2-08
Cumulative operation time selec-
tion
0
N3-03 High-slip braking stop dwell time
1.0
o2-10
Fan operation time setting
0
N3-04 High-slip braking OL time
40
o2-12
Fault trace/fault history clear func-
tion
0
N4-07 Integral time of speed estimator
0.100
o3-01
Copy function selection
0
N4-08
Proportional gain of speed estima-
tor
15
o3-02
Read permitted selection
0
N4-17 Torque adjustment gain
0.8
T1-00 Motor 1/2 selection
1
N4-18 Feeder resistance adjustment gain
1.00
T1-01 Autotuning mode selection
0
N5-01 Feed forward control selection
0
T1-02 Motor output power
0.40
N5-02 Motor acceleration time
0.178
T1-03 Motor rated voltage
200.0
*7
N5-03
Feed forward proportional gain
1.0
T1-04 Motor rated current
1.90
*6
o1-01
Monitor selection
6
T1-05 Motor base frequency
60.00
o1-02
Monitor selection after power up
1
T1-06 Number of motor poles
4
o1-03
Frequency units of reference set-
ting and monitor
0
T1-07 Motor base speed
1750
o1-04
Setting unit for frequency con-
stants related to V/f characteristics
0
T1-08
PG pulses per revolution for teach-
ing
600
o1-05
LCD brightness adjustment
3
Table 10.5 User Constants (Continued)
No.
Name
Fac-
tory
Setting
Set-
ting
No.
Name
Fac-
tory
Setting
Set-
ting
Summary of Contents for VARISPEED G7 -
Page 3: ......
Page 11: ...viii...
Page 33: ...1 16...
Page 105: ...4 20...
Page 349: ...6 154...
Page 375: ...7 26...
Page 413: ...10 24...