5
-50
Analog Inputs: H3
User constants for analog inputs are shown in the following table.
31
During speed limit (ON: During speed limit)
No
No
No
Yes
Yes
-
32
Speed control circuit operating for torque control (except when stopped).
The external torque reference will be limited if torque control is selected (internal
torque reference < external torque reference).
Output when the motor is rotating at the speed limit.
No
No
No
Yes
Yes
6-
116
33
Zero-servo end (ON: Zero-servo function completed)
No
No
No
Yes
No
-
37
During run 2 (ON: Frequency output, OFF: Base block, DC injection braking, ini-
tial excitation, operation stop)
Yes
Yes
Yes
Yes
Yes
-
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
H3-01
Signal level
selection (ter-
minal A1)
0: 0 to ±10V
[11-bit + polarity (posi-
tive/negative) input]
1: 0 to ±10V
0 or 1
0
No
A
A
A
A
A
410H
6-24
Term A1 Sig-
nal
H3-02
Gain (termi-
nal A1)
Sets the frequency when 10 V
is input, as a percentage of the
maximum output frequency.
0.0 to
1000.0
100.0%
Yes
A
A
A
A
A
411H
6-24
Terminal A1
Gain
H3-03
Bias (termi-
nal A1)
Sets the frequency when 0 V
is input, as a percentage of the
maximum frequency.
-100.0
to
+100.0
0.0%
Yes
A
A
A
A
A
412H
6-24
Terminal A1
Bias
H3-04
Signal level
selection (ter-
minal A3)
0: 0 to ±10V
[11-bit + polarity (posi-
tive/negative) input]
1: 0 to ±10V
0 or 1
0
No
A
A
A
A
A
413H
6-24
Term A3 Sig-
nal
H3-05
Multi-func-
tion analog
input (termi-
nal A3)
Select from the functions
listed in the following table.
Refer to the next page.
0 to 1F
2
No
A
A
A
A
A
414H
6-24
Terminal A3
Sel
H3-06
Gain (termi-
nal A3)
Sets the input gain (level)
when terminal 16 is 10V.
Set according to the 100%
value selected from H3-05.
0.0 to
1000.0
100.0%
Yes
A
A
A
A
A
415H
6-24
Terminal A3
Gain
H3-07
Bias (termi-
nal A3)
Sets the input gain (level)
when terminal 16 is 10V.
Set according to the 100%
value selected from H3-05.
-100.0
to
+100.0
0.0%
Yes
A
A
A
A
A
416H
6-24
Terminal A3
Bias
Set-
ting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2