User Constant Tables
5-
37
Motor 2 Setup: E4
User constants for motor 2 are shown in the following table.
* 1. The factory setting depends upon the Inverter capacity. The value for a 200 V class Inverter of 0.4 kW is given.
* 2. The setting range is 10% to 200% of the Inverter's rated output current. The values for a 200 V class Inverter of 0.4 kW is given.
* 3. If a multi-function input is set for motor 2 (H1-
= 16), the factory setting will depend upon the Inverter capacity. The value for a 200 V class
Inverter of 0.4 kW is given.
* 4. The same capacity as the Inverter will be set by initializing the constants.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
E4-01
Motor 2 rated
current
Sets the motor rated current in
1 A units.
These set values will become
the reference values for motor
protection, torque limits and
torque control.
This constant is automatically
set during autotuning.
0.32
to 6.40
*2
1.90 A
*1
No
A
A
A
A
A
321H
6-49
Motor Rated
FLA
E4-02
Motor 2 rated
slip
Sets the motor rated slip in
Hz units.
These set values will become
the reference values for slip
compensation.
This constant is automatically
set during autotuning.
0.00 to
20.00
2.90 Hz
*1
No
A
A
A
A
A
322H
-
Motor Rated
Slip
E4-03
Motor 2 no-
load current
Sets the motor no-load cur-
rent in 1 A units.
This constant is automatically
set during autotuning.
0.00 to
1.89
*3
1.20 A
*1
No
A
A
A
A
A
323H
-
No-Load
Current
E4-04
Motor 2 num-
ber of poles
(number of
poles)
Sets the number of motor
poles.
This constant is automatically
set during autotuning.
2 to 48 4 poles
No
No
A
No
A
A
324H
-
Number of
Poles
E4-05
Motor 2 line-
to-line resis-
tance
Sets the motor phase-to-phase
resistance in
Ω
units.
This constant is automatically
set during autotuning.
0.000
to
65.000
9.842
Ω
*1
No
A
A
A
A
A
325H
-
Term Resis-
tance
E4-06
Motor 2 leak
inductance
Sets the voltage drop due to
motor leakage inductance as a
percentage of the motor rated
voltage.
This constant is automatically
set during autotuning.
0.0 to
40.0
18.2%
*1
No
No
No
A
A
A
326H
-
Leak Induc-
tance
E4-07
Motor 2 rated
capacity
Set the rated output of the
motor in units of 0.01 kW.
This constant is automatically
set during autotuning.
0.00 to
650.00
0.40
*4
No
A
A
A
A
A
327H
-
Mtr Rated
Power