User Constant Tables
5-
79
U1-40
Cooling fan
operating
time
Monitors the total operating
time of the cooling fan. The
time can be set in 02-10.
(Cannot be output.)
1
hr
A
A
A
A
A
68H
FAN
Elapsed
Time
U1-42
Estimated
motor flux
Monitors the calculated value
of the motor flux. 100% is dis-
played for the rated motor
flux.
10 V: Rated motor flux
0.1
%
No
No
No
No
A
69H
Mot Flux
EST
U1-43
Motor flux
current
compensa-
tion
Monitors motor flux current
compensation value. 100% is
displayed for the rated second-
ary current of the motor.
10 V: Rated secondary cur-
rent of motor
(-10 V to 10 V)
0.1
%
No
No
No
No
A
6AH
Id Comp
Value
U1-44
ASR out-
put without
filter
Monitors the output from the
speed control loop (i.e., the
primary filter input value).
100% is displayed for rated
secondary current of the
motor.
10 V: Rated secondary cur-
rent of motor
(-10 V to 10 V)
0.0
1%
No
No
No
A
A
6BH
ASR Out-
put w Fil
U1-45
Feed for-
ward con-
trol output
Monitors the output from feed
forward control. 100% is dis-
played for rated secondary
current of the motor.
10 V: Rated secondary cur-
rent of motor
(-10 V to 10 V)
0.0
1%
No
No
No
A
A
6CH
FF Cout
Output
Con-
stant
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2