5
-66
* The factory setting depends upon the Inverter capacity. The value for a 200 V Class Inverter of 0.4 kW is given.
L8-10
Cooling fan
control selec-
tion
Set the ON/OFF control for
the cooling fan.
0: ON only when Inverter is
ON
1: ON whenever power is
ON
0 or 1
0
No
A
A
A
A
A
4B6H
-
FAN Control
Sel
L8-11
Cooling fan
control delay
time
Set the time in seconds to
delay turning OFF the cooling
fan after the cooling fan OFF
command is received.
0 to
300
60 s
No
A
A
A
A
A
4B7H
-
FAN OFF
TIM
L8-12
Ambient tem-
perature
Set the ambient temperature.
45 to
60
45
°
C
No
A
A
A
A
A
4B8H
-
temp
L8-15
OL2 charac-
teristics
selection at
low speeds
0: OL2 characteristics at low
speeds disabled.
1: OL2 characteristics at
low speeds enabled.
0 or 1
1
No
A
A
A
A
A
4BBH
-
OL2
Chara@L-
Spd
L8-18
Soft CLA
selection
0: Disable
1: Enable
0 or 1
1
No
A
A
A
A
A
4BFH
-
Soft CLA Sel
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2