6
-150
Selecting Input Terminal Functions for the DI-16H2 Digital Reference Card
The frequency reference from the DI-16H2 Card is determined by the setting of F3-01 and the 12/16-bit
switch on the Option card. The possible settings are listed in the following table.
o1-03
Frequency units
of reference set-
ting and moni-
tor
Sets the units that will be set and
displayed for the frequency refer-
ence and frequency monitor.
0:
0.01 Hz units
1:
0.01% units (Maximum
output frequency is 100%)
2 to 39:
min
−
1
units (Sets the motor
poles.)
40 to 39999:
User desired display
Set the desired values for setting
and display for the max. output
frequency.
Example: When the max. output
frequency value is 200.0, set
12000
0 to
39999
0
No
A
A
A
A
A
Display Scaling
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
Set 4-digit number
excluding the decimal
point.
Set the number of digits
below the decimal point
to display.
Summary of Contents for VARISPEED G7 -
Page 3: ......
Page 11: ...viii...
Page 33: ...1 16...
Page 105: ...4 20...
Page 349: ...6 154...
Page 375: ...7 26...
Page 413: ...10 24...
Page 417: ......